Performance Optimization Analysis of a 20 Kilo Volt (kV) Distribution Network in Dili City Using ETAP Software
DOI:
https://doi.org/10.51747/Keywords:
Distribution Network, ETAP, Feeder Loading, Substation, Voltage DropAbstract
The 20 kV power distribution network in Dili City faces technical challenges in the form of voltage drop and relatively high feeder loading levels, particularly on feeders with long distribution routes. The Dili City distribution network has a configuration centralized to a single power supply source, namely the Camea Substation, which limits the ability to transfer loads. This research aims to analyze the existing condition and to evaluate the effect of adding a new substation in the Comoro area on improving network performance. This research uses a power flow simulation–based approach employing ETAP software. The results show that under existing conditions, buses at the end of the lines experience voltage drops below the allowable standard of up to 14.30%, and four feeders have loading levels exceeding 75%. The addition of the Comoro Substation and network reconfiguration significantly improve the voltage profiles of the distribution system, ensuring compliance with SPLN 72:1987. The loading level of the Camea Substation decreases to 72% of its capacity due to the reduction of feeder load, increasing the capability for load transfer and accommodating future load growth.
References
[1] U. Zulkilpi, H. Pathoni, and D. Tessal, “Studi Analisis Keandalan Sistem Distribusi 20kV PT. PLN (Persero) UP3 Jambi ULP Kotabaru,” J. Eng., vol. 3, no. 2, pp. 92–99, 2021.
[2] B. Charrasse, J. C. Mora, G. Hawker, K. Bell, J. Bialek, and C. Maciver, “Management of extreme weather impacts on electricity grids : an international review Progress in Energy OPEN ACCESS Management of extreme weather impacts on electricity grids : an international review,” Prog. Energy, vol. 6, pp. 1–15, 2024.
[3] B. A. Anggoro, S. B. Utomo, and I. Widihastuti, “Analisa Rugi-Rugi Daya Dan Jatuh Tegangan Pada Saluran Transmisi 150 kV GI Pati Bay GI Jekulo Menggunakan ETAP 12.6.0,” Elektrika, vol. 12, no. 2, pp. 80–85, 2020.
[4] N. Ristami and Rosdiana, “Voltage Drop Study on Medium Voltage Network System at PT . Pln ( Persero ) UP3 Banda Aceh 20 kV Using Etap Software,” Fidel. J. Tek. Elektro, vol. 7, no. 1, pp. 1–10, 2025.
[5] Y. A. Rahman, S. N. Wati, R. M. Shalihah, and I. Mahmudi, “Perbaikan Tegangan Pada Jaringan Distribusi 20 kV Melalui Penempatan Pembangkit Tersebar Berbasis Particle Swarm Optimization,” JE-UNISLA, vol. 7, no. 1, pp. 42–48, 2022.
[6] A. M. Shodar, “Analisis Penempatan Transformator Distribusi Berdasarkan Drop Voltage Pada PT . PLN ( Persero ) Distribusi Lamongan Menggunakan Software Etap 19 . 0,” J. Tek. MESIN, Ind. ELEKTRO DAN Inform., vol. 2, no. 4, pp. 49–61, 2023.
[7] M. Eugen and D. Alexandra, “Optimal Substation Placement : A Paradigm for Advancing Electrical Grid Sustainability,” Sustainability, vol. 16, no. 4221, pp. 1–14, 2024.
[8] S. Ikram, K. Rehman, M. Altamash, and J. Miraj, “Design of Radial Distribution System to Study Load-Flow and Short Circuit Analysis Using ETAP Software,” Pakistan J. Eng. Technol., vol. 7, no. 1, pp. 42–49, 2024.
[9] M. Syahruddin, M. Putri, C. Cholish, and A. Abdullah, “Stabilizing Voltage and Managing Power Loss in Medium Voltage Distribution Systems Through Strategic Maneuvers,” Int. J. Electr. Electron. Res., vol. 12, no. 3, pp. 1060–1066, 2024.
[10] Nilhusna, R. Rauf, and Budiman, “Analisa Susut Tegangan dan Rugi-Rugi Daya Pada SUTM 20 kV Pada Unit PT . PLN ( Persero ) ULP Lubuk Sikaping Pasaman Sumatera Barat,” J. Mesil (Mesin Elektro Sipil), vol. 5, no. 2, pp. 117–128, 2024.
[11] M. K. Mohammed, M. Q. Taha, F. F. Salih, and F. N. Saeed, “Optimization and fault diagnosis of 132 kV substation low- voltage system using electrical transient analyzer program,” Int. J. Electr. Comput. Eng. Vol., vol. 13, no. 3, pp. 2375–2383, 2023, doi: 10.11591/ijece.v13i3.pp2375-2383.
[12] A. A. El Fergany, “Reviews on Load Flow Methods in Electric Distribution Networks,” Arch. Comput. Methods Eng., vol. 32, no. 3, pp. 1619–1633, 2025, doi: 10.1007/s11831-024-10191-7.
[13] Z. Lubis and A. Siagian, “Analisis Sistem Konfigurasi Jaringan Distribusi Penyulang 20 KV di PT . PLN ( Persero ) ULP Pakam Kota Untuk Kehandalan Jaringan Tenaga Listrik,” J. Electr. Technol., vol. 9, no. 2, pp. 53–58, 2024.
[14] A. Muhtar, Iwan, Antarissubhi, and Suryani, “Analisis Rugi Daya Jaringan Distribusi Primer PT . PLN ULP Sengkang Sulawesi,” Vertex Elektro, vol. 13, no. 01, pp. 18–24, 2021.
[15] G. Koç and I. Ömer, “The Effect of Temperature and Current on the Insulation Performance of PE and PVC Power Cables : A Finite Element Approach,” Energies, vol. 18, no. 1366, pp. 1–22, 2025.
Downloads
Published
Issue
Section
License
Copyright (c) 2026 ENERGY: JURNAL ILMIAH ILMU-ILMU TEKNIK

This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.